Controlled Egress Access Control | Texas Care Facilities
Controlled Egress Access Control for Nursing Homes, Assisted Living & Memory Care Facilities
Avenger Security helps Texas nursing homes, assisted living centers, memory care facilities, behavioral health facilities, mental health treatment areas, and 24/7 staffed care environments design and install controlled egress access control systems that balance resident safety, staff control, fire alarm release, and AHJ approval.
Under IBC 2024 Section 1010.2.13, controlled egress doors may be allowed in Group I-1 and I-2 occupancies where the clinical needs of persons receiving care require containment. These systems must be designed carefully, permitted when required, tied into the fire alarm or approved detection system, and approved before active use.
Controlled egress is allowed only when the facility and patient needs support it
Controlled egress is not ordinary card access. In a qualifying care facility, controlled egress may be allowed where residents or patients require containment for clinical, cognitive, safety, memory care, or behavioral health reasons.
This page is for 24/7 staffed care environments
Controlled egress should be used only where the facility is staffed, trained, supervised, and approved for this type of operation. Staff credentials, key switches, codes, nursing station release, fire alarm release, and emergency procedures become part of the approved life-safety sequence.
The goal is not to remove accessibility rights. The goal is to protect residents and patients who may be at risk if they leave the protected area without staff involvement.
Avenger Security can help design the complete system.
Controlled egress touches access control, door hardware, fire alarm, lock power, emergency release, staff procedures, central station monitoring, permitting, and Fire Marshal inspection. Avenger Security can help coordinate all of these pieces respectfully and professionally.
- Access control design and installation.
- Brivo or similar cloud-managed credential control.
- Fail-safe magnetic lock design.
- Fail-secure electric strike or latch hardware coordination.
- Door position monitoring and access audit history.
- Fire alarm relay tie-in and release testing.
- Austin Fire permitting and inspection support.
- Monitoring, service, repair, and future expansion.
IBC 2024 Section 1010.2.13 — controlled egress doors in Groups I-1 and I-2
IBC 2024 Section 1010.2.13 addresses controlled egress doors in Group I-1 and I-2 occupancies. Controlled egress may be allowed when the clinical needs of persons receiving care require containment.
Clinical Need
The controlled egress arrangement must be based on the clinical, cognitive, behavioral, or safety needs of the residents or patients receiving care.
Sprinkler or Smoke Detection
The building or protected area must be evaluated for required automatic sprinkler protection or approved smoke detection protection.
Fire Alarm Release
Controlled egress locks must release upon activation of the fire alarm, sprinkler, smoke detection, or approved life-safety system sequence.
Loss of Power Release
Fail-safe locking components should release when power to the electrical locking system or lock mechanism is lost.
Staff Release Location
A release switch is typically required at the fire command center, nursing station, or other approved location.
One Controlled Door Before Exit
The egress path should be reviewed so occupants are not required to pass through more controlled egress doors than allowed before reaching an exit.
Emergency Plan
Unlocking procedures should be included in the facility’s emergency planning and preparedness documents.
Staff Credentials
Clinical staff must have keys, codes, credentials, or other approved means to operate the controlled egress locking system.
Listed Hardware
Electromagnetic, electromechanical, access control, and special locking components must be listed and installed according to the approved design.
Do not install controlled egress like a normal maglock
A controlled egress door is a life-safety system, not just an access control door. The lock, reader, door contact, power supply, release switch, fire alarm relay, sequence of operation, staff procedure, and AHJ approval all matter.
If a facility installs magnetic locks without the proper fire alarm release, power loss release, staff release, emergency lighting, signage, drawings, or inspection approval, the system can fail final inspection and create a serious life-safety issue.
Example controlled egress design reference
A practical controlled egress project may include multiple perimeter doors with Brivo access control, credentialed entry, staff-controlled exit, door position monitoring, request-to-exit devices, electrically controlled locking hardware, fire alarm tie-in, and central station fire monitoring coordination.
The controlled egress configuration should not be placed into active operation until the fire alarm interface is complete, the door release sequence has been tested, and the Fire Marshal or AHJ has approved the final installation.
Best practice: use fail-safe locks in conjunction with fail-secure hardware
For many nursing home, assisted living, memory care, and behavioral health applications, Avenger Security recommends designing the opening with both fail-safe and fail-secure concepts working together.
Fail-Safe Magnetic Lock
The fail-safe lock provides the controlled egress hold. It should release on fire alarm activation, required smoke or sprinkler activation, approved staff release, emergency release, and loss of lock power.
Fail-Secure Door Hardware
The fail-secure hardware keeps the facility secure and the door mechanically latched. This may include an electric strike, electrified lockset, controlled latch retraction, or other approved locking hardware.
Why both are often needed
The magnetic lock provides controlled egress release. The fail-secure hardware provides physical security and latching. This dual approach helps avoid relying on one device to do everything and gives the AHJ a clearer sequence of operation.
Facilities this applies to
Controlled egress is most commonly considered for care environments where the facility is staffed and the residents or patients require supervision, protection, or containment.
Nursing Homes
Skilled nursing and long-term care facilities with supervised residents, staff-controlled areas, fire alarm systems, and perimeter safety concerns.
Assisted Living Centers
Facilities providing 24-hour supervised residential care where resident safety, visitor control, staff access, and emergency release must be coordinated.
Memory Care Units
Alzheimer’s, dementia, and cognitive-care environments where wandering or elopement risk requires controlled egress and staff-managed release.
Behavioral Health Facilities
Supervised treatment settings where patient safety, staff safety, and controlled movement must be balanced with fire alarm release and emergency egress.
Mental Health Treatment Areas
Areas where ordinary card access is not sufficient because staff may need to control exit under an approved care and emergency procedure.
Supervised Residential Care
24/7 staffed care facilities where access control, fire alarm monitoring, resident protection, and AHJ approval must work together.
Austin Fire permit and plan review is required for this type of work
In Austin, controlled egress, magnetic locks, delayed egress, special locking arrangements, and access control that affects egress or fire alarm release should be treated as an Austin Fire / AHJ review item. A permit and plan review package should be expected before active use.
Electrical Locking / Access Control Submittal
Austin Fire may require a plan submittal for electrical locking systems, access control, maglocks, controlled egress, delayed egress, and fire alarm release interfaces.
Fire Alarm Tie-In Drawings
The drawings should show how the fire alarm system releases the fail-safe locking components during alarm activation, required detection events, and power loss conditions.
Sequence of Operation
The submittal should explain how the door operates during credentialed entry, staff release, nursing station release, emergency release, fire alarm activation, and relock.
Device Cut Sheets
The AHJ may request cut sheets for magnetic locks, electric strikes, Brivo door controllers, readers, power supplies, release switches, fire alarm relays, door contacts, and exit hardware.
Inspection and Testing
Before final approval, each controlled opening should be tested for credential access, staff release, fire alarm release, power loss behavior, door status, and central station monitoring.
Do Not Activate Before Approval
The controlled egress function should remain inactive until the fire alarm interface is complete, the installation is tested, and the Fire Marshal or AHJ approves the final system.
Controlled egress system components
- Brivo access control or other approved access control platform.
- Credential readers for entry and staff-controlled exit.
- Fail-safe magnetic locks for controlled egress release.
- Fail-secure electric strikes, electrified locksets, or latch hardware.
- Door position sensors for forced-open and held-open events.
- Request-to-exit, staff release, or approved release devices.
- Nursing station, fire command center, or approved release switch.
- Fire alarm relay modules and release wiring.
- Lock power supplies designed around the approved release sequence.
- Emergency lighting, signage, and approved emergency procedures.
What Avenger Security can handle
- Site review and door survey.
- Controlled egress design and sequence of operation.
- Access control installation and programming.
- Fail-safe and fail-secure hardware coordination.
- Fire alarm system tie-in and release testing.
- Fire alarm monitoring and central station coordination.
- Austin Fire permit and plan review support.
- Resubmittals and Fire Marshal comment response.
- Final inspection preparation and testing.
- Ongoing maintenance, service, troubleshooting, and upgrades.
Our controlled egress project process
Avenger Security approaches controlled egress like a life-safety project, not just an access control installation.
Review facility use and occupancy
We review whether the facility is a nursing home, assisted living, memory care, behavioral health, mental health, supervised residential care, or other care environment where controlled egress may apply.
Survey each controlled door
We inspect the doors, frames, closers, existing locks, crash bars, strikes, fire rating, door contacts, wire paths, power supplies, and current access control equipment.
Design the fail-safe and fail-secure sequence
We determine how the magnetic lock, fail-secure hardware, fire alarm relay, reader, release switch, door contact, and lock power will operate under every required condition.
Prepare permit and plan review support
We help prepare the controlled egress sequence, access control notes, device locations, cut sheets, fire alarm tie-in details, and submittal support for Austin Fire or the applicable AHJ.
Install, program, and test
We install the access control, lock hardware, fire alarm interface, release devices, monitoring components, and door status devices, then test the full sequence before final inspection.
Support inspection and ongoing service
We support Fire Marshal inspection, signal testing, staff handoff, ongoing service, hardware upgrades, monitoring, troubleshooting, and future door additions.
Important code, ADA, and AHJ note
Controlled egress, delayed egress, magnetic locks, fail-safe release, fail-secure hardware, fire alarm tie-in, sprinkler/smoke detection release, emergency lighting, signage, ADA accessibility, staff release, and first responder access must be reviewed for the specific facility.
Final requirements depend on the adopted code, occupancy classification, local amendments, resident care needs, building layout, fire alarm system, sprinkler or smoke detection system, and the authority having jurisdiction.
Frequently asked questions
Can a nursing home or assisted living facility require credentials to leave?
In a qualifying controlled egress care environment, staff credentials, keys, codes, or approved release methods may be used to control exit under the approved sequence. This must be based on resident or patient care needs and approved by the AHJ.
Does controlled egress apply to every assisted living facility?
No. The facility type, occupancy classification, resident needs, staffing, fire protection systems, door location, and AHJ approval all matter. Controlled egress should not be assumed without review.
Why use fail-safe magnetic locks with fail-secure hardware?
The fail-safe magnetic lock provides the controlled egress release function, while the fail-secure hardware keeps the door mechanically secure and latched. Together, they provide a clearer and more reliable sequence for security and life safety.
Should the magnetic lock have battery backup?
Typically, the fail-safe magnetic lock circuit should not be backed up in a way that defeats required release on loss of power. Lock power design must be reviewed and approved for the specific controlled egress sequence and AHJ requirements.
Does the system need to tie into the fire alarm system?
Yes, controlled egress systems commonly require fire alarm, sprinkler, smoke detection, or approved life-safety system interface so the controlled locking component releases during required emergency conditions.
Is an Austin Fire permit required?
For Austin projects involving controlled egress, magnetic locks, delayed egress, electrical locking, or access control that affects egress or fire alarm release, an Austin Fire / AHJ permit and plan review should be expected before the system is placed into active use.
Can Avenger Security help if another contractor started the project?
Yes. Avenger Security can review existing plans, door hardware, fire alarm tie-ins, permit status, rejected comments, installation deficiencies, and inspection issues to help determine the path forward.
Please make contact with Avenger Security before installing controlled egress locks
Need help upgrading your local door hardware, adding controlled egress access control, tying locks into the fire alarm system, preparing for Austin Fire permitting, or fixing a project that is already in trouble? Avenger Security can help.
Avenger Security provides access control, fire alarm, security alarm, video surveillance, intercom, monitoring, gate access, and low-voltage security services. Controlled egress requirements vary by facility, occupancy, code cycle, local amendment, fire alarm system, resident care needs, and AHJ interpretation. Final design and activation should be approved by the authority having jurisdiction.
Fire Alarm Testing in Care Facilities
For facility-specific Texas requirements, review these related guides:
Texas HHSC Fire & Life Safety Compliance
Local fire marshal approval and Texas Health and Human Services licensing requirements are not always identical. Learn why early coordination and experienced fire and life-safety planning matter for care facilities: Texas HHSC Fire & Life Safety Compliance Guide.
Managed Access Control Blog: Design, Hardware & Compliance
View all-
Brivo ACS300: Two-Door Cloud Access Controller ...
Plan a Brivo ACS300 deployment around its two wired doors, subscription, readers, lock power, door monitoring, network and future expansion.
Brivo ACS300: Two-Door Cloud Access Controller ...
Plan a Brivo ACS300 deployment around its two wired doors, subscription, readers, lock power, door monitoring, network and future expansion.
-
Austin Access Control Door Evaluation: What We ...
New clients considering new services receive an on-site visit and up to one hour of consultation at no cost. Basic diagnostic service is $95.00 after the first hour; technical work...
Austin Access Control Door Evaluation: What We ...
New clients considering new services receive an on-site visit and up to one hour of consultation at no cost. Basic diagnostic service is $95.00 after the first hour; technical work...
-
Request-to-Exit (REX) Sensors: What They Do—and...
Learn how REX inputs, door-position switches and free-egress hardware work together—and why a REX sensor should not be mistaken for the door’s only unlocking method.
Request-to-Exit (REX) Sensors: What They Do—and...
Learn how REX inputs, door-position switches and free-egress hardware work together—and why a REX sensor should not be mistaken for the door’s only unlocking method.
Featured Access Control Hardware — Heavy-Duty & Fail-Secure
Our featured access control collection showcases pro-grade components we trust in the field—Brivo ACS controllers, OSDP readers, Command Access MLRK kits for panic hardware, Adams Rite/HES fail-secure strikes, mag-resistant door contacts, request-to-exit sensors, and supervised power supplies with battery backup. Every item is curated for code-compliant installations, event accountability, and smooth integration with video and alarms—built for the demands of Austin and Central Texas.
-
Rosslare 26-Bit 125 kHz EM Clamshell Cards – 25 Pack
Regular price $47.03 USDRegular priceSale price $47.03 USD -
Brivo B-BUC3-37-SF25 Unified Credential Fobs – 37-Bit, 25-Pack
Regular price $308.00 USDRegular priceSale price $308.00 USD -
Rosslare AYC-Q64B Proximity + PIN Reader/Controller
Regular price $305.00 USDRegular priceSale price $305.00 USD -
Altronix SMP3 6/12/24VDC 2.5A Power Supply/Charger
Regular price $32.34 USDRegular priceSale price $32.34 USD -
Brivo B-BUC3-56-SF25 Unified Credential Fobs – 56-Bit, 25-Pack
Regular price $334.00 USDRegular priceSale price $334.00 USD -
Brivo B-BUC3-37-SC50 Unified Credential Cards – 37-Bit, 50-Pack
Regular price $465.00 USDRegular priceSale price $465.00 USD -
Brivo B-BUC3-56-SC50 Unified Credential Cards – 56-Bit, 50-Pack
Regular price $445.00 USDRegular priceSale price $445.00 USD -
Brivo B-BSPSF-B Black OSDP Single-Gang Smart Reader
Regular price $490.00 USDRegular priceSale price $490.00 USD